MSX2500L Tomography Inspection System

 

Feature:

  • Newest Technology; Tomography by lamina-graph system.
  • For Large Size Board; Tomography by lamina-graph system.
  • High Speed;The time of a tomogram is 1 seconds slightly.
  • High Resolution: The accuracy of a image is 25 microns or more.
  • Low Price; The price is reasonable
  • Easy Maintenance: The X ray generator is closed type with long life.
  • Semi-In-line possible: by loader un-loader.
  • Both-Sided: Inspection is possible to piled BGA.
  • Multi Layer Check: The check of the multilayered board is possible.

  • Abstract:

    MSX2500 is tomography inspection system by lamina-graphy, It is the best inspection system to the multi-sided mounting board with high density. The system is able to operate like in-line test machine by linking conveyor system, such as board loader and un-loader.

    The lamina-graphy is the theory which synchronized two items in from three items such as a X ray generator, a detector, and a test material.MSX2500 is synchronized of the X ray generator and the detector, and there are rotated within around 1 second. and also they themselves rotate. If it does so, a image focusing will be fixed, and the fixed position of the focus can be change by the relational position change of the two items.
    The accuracy of the image is 25 micron or less when the image area is 10 x 8mm. and the position of FP can be chosen in a height of within 13mm.

     

     

    MSX2000M

    MSX2500L

     

     

    lamina-grafy

    MSX2000M Lamina-Graphy System

     

     

    Information of the X Ray:

    The X ray is an electromagnetic wave with short wave-length, it can pass through between an atom and atoms. The wavelength of visible is about several microns, but the x ray is about Å. and a penetration is in inverse proportion to the density. Generally, It is managed by the rule of the Government. It is because, the x ray gives a physiologically effect to a live-body.
    MSX2500 is managed of the radiation less than 1 micro Sv/ Hours / cm. It is lower than the color television, the CRT of the color television is always emitting the several micro Sv/H of radiation. and also there is same levels of radiation in the atmosphere always.
    The radiation of MSX2500 is controlled by the very safety level. It is very safety zone. Furthermore, MSX2500 is used of the X ray in the sealed box. and it is with sufficient interlock function.

     

     

    Test operation Images by MSX2500L

    Laminate BGA

     

    This is an test sample, in case of two kinds of the BGA is mounted of surface and reverse-side at the board.

    The tested image of the position B level is displayed on the screen when the FP of the tomogram is setup as B level.

    And also test image of the position A will be displayed on the screen when the FP is setuped as A level.

    The tested image of the C will be displayed when tested by the fluoroscopy system. In this case, inspection will be impossible by the image A and B overlaps.

    The test position of the FP can be adjust in the height of a maximum of 13mm from the surface of the test table.

    .

     

     

    top page

    A image
    The test image at A.

     

    b image
    The Test image at B

     

    c image

    TheTest image by C

     

    SAMPLE IMAGES by Auto-Checked

    SAMPLE IMAGE for Inspection

     

     

    Dimensions:

     boday demension

    MSX2500L: 1300W x 1600H x 1550Dmm

     


    Semi-In-Line System:
    MSX2500 can be check with high speed, it will be inspection around 1 second by 10 x 8 mm area. And also the system can be test by the programmable XY automatic controller. Therefore, it can operate as automatic X ray tomography inspection system by with the optional loader with the un-loader system.

     

     

    instruct

     

    MSX2500:semi- In-Line type Tomography System

     